Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cureus ; 16(3): e55475, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38571861

RESUMO

A 53-year-old man with diabetes mellitus presented to the emergency department with a fever and impaired mobility. A preliminary diagnosis of urinary tract infection was made based on dysuria and pyuria. History-taking revealed a history of gait disturbance and difficult urination. A thorough physical examination suggested a spinal abnormality. MRI scan revealed a narrow spinal canal due to ossification of the posterior longitudinal ligament and diffuse idiopathic skeletal hyperostosis. Throughout the diagnostic process, we employed both vertical tracing to investigate the causes of urinary tract infection and horizontal tracing to explore comorbidities such as diabetes. Additionally, we introduced appropriate social security and support systems under the name of diagnostic excellence.

2.
Acta Med Okayama ; 68(5): 263-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25338482

RESUMO

Nursing support might help patients with chronic hepatitis C (CHC) remain in good mental and physical condition during interferon (IFN) therapy. However, the effects of nursing support have not been studied adequately in this context. This case-control study evaluated the effects of nursing support during IFN therapy. Twenty-four CHC patients who received pegylated IFN and ribavirin were enrolled. Nurses advised patients on the maintenance of their mental and physical condition at weekly visits, based on the results of written questionnaires. An additional 24 patients who received IFN therapy without nursing support and who were matched for age, sex, platelet count, viral serogroup and IFN regimen were selected with propensity score matching as controls. The patients with nursing support during IFN therapy achieved higher sustained virological responses (79%) than those without nursing support (58%). Adherence to the IFN and ribavirin regimens at 24 weeks of therapy were slightly higher in the patients with nursing support than those without it, but these differences were not statistically significant. Adherence to ribavirin after 24 weeks of therapy was significantly higher in those with nursing support than those without it (93% and 66%, p=0.045). These results suggested that nursing support services could contribute to the virological responses of CHC patients by promoting drug-regimen adherence.


Assuntos
Antivirais/uso terapêutico , Hepatite C Crônica/tratamento farmacológico , Interferon-alfa/uso terapêutico , Enfermeiros de Saúde Comunitária , Polietilenoglicóis/uso terapêutico , Estudos de Casos e Controles , Quimioterapia Combinada , Feminino , Hepatite C Crônica/psicologia , Humanos , Interferon alfa-2 , Masculino , Pessoa de Meia-Idade , Cooperação do Paciente/psicologia , Proteínas Recombinantes/uso terapêutico , Ribavirina/uso terapêutico , Inquéritos e Questionários , Resultado do Tratamento
3.
Appl Opt ; 49(18): 3511-21, 2010 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-20563204

RESUMO

X-ray astronomy research is often limited by the size, weight, complexity, and cost of functioning x-ray optics. Micropore optics promises an economical alternative to traditional (e.g., glass or foil) x-ray optics; however, many manufacturing difficulties prevent micropore optics from being a viable solution. Ezoe et al. introduced microelectromechanical systems (MEMS) micropore optics having curvilinear micropores in 2008. Made by either deep reactive ion etching or x-ray lithography, electroforming, and molding (LIGA), MEMS micropore optics suffer from high micropore sidewall roughness (10-30nmrms) which, by current standards, cannot be improved. In this research, a new alternating magnetic-field-assisted finishing process was developed using a mixture of ferrofluid and microscale abrasive slurry. A machine was built, and a set of working process parameters including alternating frequency, abrasive size, and polishing time was selected. A polishing experiment on a LIGA-fabricated MEMS micropore optic was performed, and a change in micropore sidewall roughness of 9.3+/-2.5nmrms to 5.7+/-0.7nmrms was measured. An improvement in x-ray reflectance was also seen. This research shows the feasibility and confirms the effects of this new polishing process on MEMS micropore optics.

4.
Appl Opt ; 49(6): 1007-11, 2010 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-20174169

RESUMO

The x-ray reflectivity of an ultralightweight and low-cost x-ray optic using anisotropic wet etching of Si (110) wafers is evaluated at two energies, C K(alpha)0.28 keV and Al K(alpha)1.49 keV. The obtained reflectivities at both energies are not represented by a simple planar mirror model considering surface roughness. Hence, an geometrical occultation effect due to step structures upon the etched mirror surface is taken into account. Then, the reflectivities are represented by the theoretical model. The estimated surface roughness at C K(alpha) (approximately 6 nm rms) is significantly larger than approximately 1 nm at Al K(alpha). This can be explained by different coherent lengths at two energies.

5.
J Electron Microsc (Tokyo) ; 59(1): 17-26, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19717388

RESUMO

A new energy dispersive X-ray spectrometer (EDS) with a microcalorimeter detector equipped with a transmission electron microscope (TEM) has been developed for high- accuracy compositional analysis in the nanoscale. A superconducting transition-edge-sensor-type microcalorimeter is applied as the detector. A cryogen-free cooling system, which consists of a mechanical and a dilution refrigerator, is selected to achieve long-term temperature stability. In order to mount these detector and refrigerators on a TEM, the cooling system is specially designed such that these two refrigerators are separated. Also, the detector position and arrangement are carefully designed to avoid adverse affects between the superconductor detector and the TEM lens system. Using the developed EDS system, at present, an energy resolution of 21.92 eV full-width-at-half maximum has been achieved at the Cr K alpha line. This value is about seven times better than that of the current typical commercial Si(Li) detector, which is usually around 140 eV. The developed microcalorimeter EDS system can measure a wide energy range, 1-20 keV, at one time with this high energy resolution that can resolve peaks from most of the elements. Although several further developments will be needed to enable practical use, highly accurate compositional analysis with high energy resolution will be realized by this microcalorimeter EDS system.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...